Coaxial Cable

09:53 / Posted by tech data /

Because the coaxial line carries a DC current to supply power to the transverter, gas-discharge surge arrestors are required. Do not use quarter-wave stub or solid-state type surge arrestors.

When the entire coaxial cable, from the building entrance to the transverter, is encased in steel conduit, no surge arrestors are required. However, local electrical codes require that the conduit be grounded where it enters the building.

When steel conduit is not used to encase the cable, each cable requires one surge arrestor within 2 feet of the building entrance, and another surge arrestor within 10 feet of the transverter .